Self-Operated CO2 Detection Tube with 170℃ Auto Burst and 12.1Mpa Maximum Pressure for Fire Protection

جزئیات محصول

محل منبع: گوانگژو، چین

نام تجاری: XINGJIN

گواهی: GSG\TUV\GB6653-2008

شماره مدل: WZ-Q/T-EZ6-XJ60;WZ-Q/T-EJ45-XJ60

شرایط پرداخت و حمل و نقل

مقدار حداقل تعداد سفارش: سیستم 100 ست

قیمت: Pricing based on quantity

جزئیات بسته بندی: جعبه چوبی یا جعبه بیرونی تخته سه لا با کیسه یا کاغذ حباب

زمان تحویل: 15-20 روز

شرایط پرداخت: T/T، L/C

قابلیت ارائه: 30000s/ماه

بهترین قیمت رو بدست بیار
جزئیات محصول
برجسته کردن:

170℃ Auto Burst Fire Detection Tube,12.1Mpa Maximum Pressure Fire Extinguisher Tube,5.7Mpa Working Pressure CO2 Detection Tube

,

12.1Mpa Maximum Pressure Fire Extinguisher Tube

,

5.7Mpa Working Pressure CO2 Detection Tube

تراکم:
1.05g/cm3 ±0.1g/cm3
دمای نقطه ذوب:
170℃±10℃
فشار کار اسمی:
5.7 مگاپاسکال
حداکثر فشار کار:
12.1 مگاپاسکال
محدوده دمای عملیاتی:
(0 ~ 49) ℃
حداکثر طول لوله تشخیص آتش سوزی:
25 متر
حداکثر ضریب بارگیری:
0.6 کیلوگرم در لیتر
تراکم:
1.05g/cm3 ±0.1g/cm3
دمای نقطه ذوب:
170℃±10℃
فشار کار اسمی:
5.7 مگاپاسکال
حداکثر فشار کار:
12.1 مگاپاسکال
محدوده دمای عملیاتی:
(0 ~ 49) ℃
حداکثر طول لوله تشخیص آتش سوزی:
25 متر
حداکثر ضریب بارگیری:
0.6 کیلوگرم در لیتر
توضیحات محصول

Fire Detectors/Fire detection tube


What is a fire detection tube?
  The fire detector, originating in Europe, is a simple, low-cost, and highly reliable independent automatic fire extinguishing system. It does not rely on any power source and operates solely on its own pressurization. This system is primarily designed for enclosed spaces such as electrical control boxes and machine rooms. The fire detector fire extinguishing device consists of a pressurized fire detector connected to it, which detects the fire and delivers the extinguishing medium to the protected area through the fire detector itself (direct system) or nozzles (indirect system).

  The fire detector is a new product developed in the high-tech field, combining long-term leak resistance, flexibility, and effective temperature sensing. The main components of the fire detection system are designed and manufactured under a strict quality control system. This product can use a variety of different extinguishing media, such as dry powder extinguishing agents, HFC-227, HFC-236 (low pressure), and carbon dioxide extinguishing agents (high pressure).
 

Self-Operated CO2 Detection Tube with 170℃ Auto Burst and 12.1Mpa Maximum Pressure for Fire Protection 0 Self-Operated CO2 Detection Tube with 170℃ Auto Burst and 12.1Mpa Maximum Pressure for Fire Protection 1 Self-Operated CO2 Detection Tube with 170℃ Auto Burst and 12.1Mpa Maximum Pressure for Fire Protection 2


 

Advantages of Fire Detectors:
  Fire detection devices can extinguish fires instantly and effectively, and also offer the following advantages:
★ Unique extinguishing effect, effectively extinguishing fires in their early stages. The device automatically activates upon contact with fire, requiring no power supply or manual operation.

★ Ideal for unattended equipment and locations requiring intensive protection.

★ Rapid detection response time, reducing losses caused by the spread of fire.

★ Fire detectors are not affected by location and can be inserted into various complex flammable spaces or equipment.

  Fire detectors are essentially linear detectors, both detecting fire and releasing extinguishing agents. Due to the small amount of extinguishing agent used, environmental pollution and damage are reduced, significantly lowering the cost of each fire suppression operation.

Easy to install and occupies minimal space.

  The simple design minimizes installation and maintenance costs. It is not fully submersible, so release will not injure personnel in the protected area.

  It will not cause false alarms or accidental releases due to oil, dust, or other contaminants.

The device has no electrical components, and its operation is unaffected by vibration or impact. Because the fire detection tube is flexible, it can be placed at various wiring locations. This feature fills the gap in existing fire protection products that cannot extinguish this type of fire.

 

How does it work?

  The fire detector, originating in Europe, is a simple, low-cost, and highly reliable independent automatic fire extinguishing system. It does not rely on any power source; it operates solely on its own pressurized power. This system is primarily designed for enclosed spaces such as electrical control boxes and machine rooms. The fire detector fire extinguishing device consists of a pressurized fire detector connected to it, which detects the fire and delivers the extinguishing medium to the protected area through the fire detector itself (direct system) or nozzles (indirect system).

  The fire detector is a new product developed in the high-tech field, combining long-term leak resistance, flexibility, and effective temperature sensing. The main components of the fire detection system are designed and manufactured under a strict quality control system. This product can use various extinguishing media, such as dry powder extinguishing agents, HFC-227, HFC-236 (low pressure), and carbon dioxide extinguishing agents (high pressure).

  The fire detection device can instantly and effectively extinguish fires and has the following advantages:

★ Unique extinguishing effect, effectively extinguishing fires in their early stages. The device automatically activates upon contact with fire, requiring no power supply or manual operation.

★ Ideal for unattended equipment and locations requiring intensive protection.

★ Rapid detection response time, reducing losses caused by the spread of fire.

★The fire detection tube is unaffected by location and can be inserted into various complex flammable spaces or equipment.
 

Self-Operated CO2 Detection Tube with 170℃ Auto Burst and 12.1Mpa Maximum Pressure for Fire Protection 3 Self-Operated CO2 Detection Tube with 170℃ Auto Burst and 12.1Mpa Maximum Pressure for Fire Protection 4   This fire extinguishing system uses a pressurized non-metallic hose that automatically bursts within a certain temperature range, spraying extinguishing agent or transmitting fire signals. This hose is directly placed at the potential ignition point and acts as a fire detection element. At a temperature of 160°C, the hose automatically bursts due to internal pressure, creating a spray hole that directly sprays the extinguishing agent to the fire source.   
  The system responds quickly and accurately, releasing extinguishing agents more promptly and effectively, resulting in stronger targeted and effective fire suppression. It can quickly and effectively detect and extinguish fires in their initial stages, making it an early-stage fire suppression system. This represents a significant advancement compared to traditional fixed gas fire suppression systems and dry powder fire suppression systems, which only extinguish fires in entire rooms or large spaces after they have already spread.

  The fire detection tube is essentially a linear detector, capable of both detecting fire and releasing extinguishing agents. Due to the small amount of extinguishing agent used, it reduces pollution and damage to the surrounding environment, significantly lowering the cost of each firefighting operation.

  Installation is simple and it occupies minimal space.

  The simple design minimizes installation and maintenance costs. It is not fully submersible, so release will not harm personnel in the protected area.

  It will not cause false alarms or accidental releases due to oil, dust, etc.

  This device has no electrical components, and its operation is unaffected by vibration or impact. Because the fire detection tube is a flexible tube, it can be placed arbitrarily at various wiring locations. This feature fills the gap in existing fire protection products that cannot extinguish this type of fire source.

 

How to order?

  Contact us and we will provide you with our product models and specific information.

  Tell us the model you need, the model you require customization for, and the quantity, and we will provide you with a detailed quote.

  If you are unsure which model you need, please tell us your fire safety space information, and we have a dedicated designer to assist you.

  Finally, we also offer professional logistics to provide you with one-stop service.


Why choose us?​
Self-Operated CO2 Detection Tube with 170℃ Auto Burst and 12.1Mpa Maximum Pressure for Fire Protection 5

 

محصولات ما
محصولات مشابه
3Kg Fm200 آتش نشانی با استاندارد GB25972-2010 ویدیو
بهترین قیمت رو بدست بیار
سیستم شناسایی آتش برای حفاظت موثر ویدیو
بهترین قیمت رو بدست بیار